Contact Us: (+86 755) 81709985 / 81709986
                    +86 18027664749, oscar@ametertech.com
 

Cable remote ultrasonic water-meter

Cable remote ultrasonic Water Meter

Models:LXCN-15/20/25/32/40       

Usage:Figuring out the water flow speed by measuring the ultrasonic wave velocity of change that caused by water flow in the pipe, then, obtain the volume of water passed by. Ultrasonic water meter is a credible instrument for trade settlement.


  • Features

  1. Low start flow, long range of measurement

  2. Counting forward and reverse flow, pinpoint accuracy and stability

  3. Low power design & long battery longevity

  4. Equipped with leaky detection & burst detection

  5. Varieties of communication model, wired M-bus network, radio Ad-Hoc network, Bluetooth with smartphone APP can be selected as need, easy to access the meter’s data for monitoring

  6. Large-capacity data storage, recording meter’s running information including 36 months of time-slicing information for the district metering monitoring

  7. No wear & no moving parts, low head loss

  8. Strengthen design for waterproof, IP68 type tested, suitable for installation in meter pits

  9. Can be fixed in almost any direction, not must to be vertical or horizontal


  • Main technical parameters

  • Pipe material:Copper

  • Body material:PPS plus fiber glass

  • Ambient temperature: 0~50℃

  • Fluid temperature: 0+℃~30℃

  • Working pressure: ≤1M Pa

  • Installment environment: Class B

  • Electromagnetic environment: E1

  • Velocity sensitivity level: U10, D5

  • Electron circuit: working voltage 3.6 ~3.2V, minimum current≤5μA

  • Battery: 3.6V high power lithium battery, 10 years of effective service-life at tBAT ≤30℃ on base module

  • Interactive button: touch-sensitive button

  • Wireless reading: LoRa communication

  • Wired network: M-bus, support multi-protocols

  • Self-service reading: SNFC adapter plus smartphone

  • Data storage: records of running in 36 months

  • Implementing standards:

GB/T 778.1~3-2007 Measurement of water flow in fully charged closed conduits—Meters for cold potable water and hot water CNS

ISO 4064-1~3:2014 Water meters for cold potable water and hot water


  • Flow technical parameters

Nominal diameter 

Starting flow

Minimum flow

Bounded flow

Common flow

Overload flow

Accuracy level

 (mm)

Qst (L/h)

Q1 (L/h)

Q2 (L/h)

Q3 (m3/h)

Q4 (m3/h)

15

4

12.5

20

2.5

3

2

20

5

20

32

4

5

25

6

39

62

6.3

7

32

8

62

99

10

12

40

10

80

128

16

19


  • Outline specification size

Nominal diameter

Length

Width

Height

Connection thread
d

(mm)

(mm)

(mm)

(mm)

15

165

86

78

G1/2B

20

195

90

80

G3/4B

25

225

95

85

G1B

32

230

100

90

G3/2B

40

245

106

96

G2B


  • Relative error of measurement

Low segment (Q1≤Q<Q2): -5%≤relative error ε≤5%
Middle segment (Q2≤Q<Q3): -1%≤relative error ε≤1%
High segment (Q3≤Q<Q4): -1%≤relative error ε≤1%


  • Curve of flow error


  • Curve of head loss

COPYRIGHT© 2016 Shenzhen A-meter technology Co.,Ltd.   Guangdong ICP 1234567-1

 